Regarding the OP’s question (the following analysis is for reference only):
This issue with the steel strands can be remedied.

  1. Judging by the cut marks, the strands were severed using hydraulic tools. Specialized hydraulic shears or portable cutters are typically used for this purpose; however, a cut made by a standard cutter would usually leave a flat, clean cross-section.
  2. The two strands are different: one is a bonded strand, and the other (red) is an unbonded strand. (Please refer to this article for the differences between them; their application scenarios vary slightly, though it is possible for an unbonded strand to be stripped of its sheathing for use.)
  3. Steel strands generally require anchors to secure them. The exposed sections in the photo appear to be at the edge of the wall; if this is indeed the edge, excavating a bit further into the wall should reveal the anchors or steel plates securing the strands.
  4. If no anchors are visible, it implies the strands are under tension. Long-term structural stability must be considered; while there may be no immediate issues, the building could develop minor cracks over time due to crustal movements or environmental factors.
  5. It is recommended to first determine whether the two strands are under tension or to contact the contractor to see if they are aware of the situation.

Solution: An anchor connector can be used to join the two steel strands together.